UNAM 12P1914/S14D 10145833

Technical data
general data
scanning range Sd
  • 5 … 70 mm
scanning range far limit Sde
  • 5 … 70 mm
hysteresis typ.
  • 4 % Sde
repeat accuracy
  • < 0,5 mm
temperature drift
  • < 0,18 % Sde/K
response time ton
  • < 10 ms
release time toff
  • < 10 ms
sonic frequency
  • 380 kHz
adjustment
  • external Teach-in
alignment aid
  • target indication flashing
output indicator
  • LED green
Description

electrical data
voltage supply range +Vs
  • 12 … 30 VDC
current consumption max. (no load)
  • 35 mA
output circuit
  • PNP make function (NO)
output current
  • < 200 mA
voltage drop Vd
  • < 2 VDC
residual ripple
  • < 10 % Vs
short circuit protection
  • yes
reverse polarity protection
  • yes
mechanical data
type
  • cylindrical threaded
housing material
  • brass nickel plated
width / diameter
  • 12 mm
height / length
  • 100 mm
connection types
  • connector M12
ambient conditions
operating temperature
  • 0 … +60 °C
protection class
  • IP 67