Ordering details | |
Product type description | RSS 36-D-ST |
Article number | 101213954 |
EAN Code | 4030661410623 |
eCl@ss | 27-27-24-01 |
Mechanical data | |
Design of electrical connection | Connector M12, 8-pole |
mechanical installation conditions | not flush |
Actuating planes | Actuation from side |
Active area | lateral |
Switch distance Sn | 12 mm |
Ensured switch distance ON Sao | 10 mm |
Ensured switch distance OFF Sar | 20 mm |
hysteresis | max. 2 mm |
Repeat accuracy R R | < 0,5 mm |
notice | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm. see drawing: Operating principle minimum distance 100 mm in case of approach from side |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 55 HZ, Amplitude 1 mm |
Latching (Y/N) | No |
Latching force | - |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +70 |
Storage and transport temperature | |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Temperature resistance cable | |
- min. Temperature resistance | −30 in position of rest, −10 in Movement |
- max. Temperature resistance | +105 |
Protection class | IP65, IP67, IP69 to IEC/EN 60529 |
Protection rating | III |
Air clearances and creepage distances To IEC/EN 60664-1 | |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Overvoltage category | III |
- Degree of pollution | 3 |
Electromagnetic compatibility (EMC) | |
EMC rating | to IEC 60947-3 |
Interfering radiation | to IEC 61000-6-4 |
Electrical data | |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Voltage type | DC |
Switch frequency | 1 |
Rated insulation voltage Ui | 32 VDC |
Rated operating voltage Ue (stabilised PELV) | |
- Min. Rated operating voltage | 20.4 VDC |
- Max. Rated operating voltage | 26.4 VDC |
Operating current Ie | 0,6 A |
No-load current I0 | 0,1 A |
Required rated short-circuit current | 100 A |
notice | The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current |
Electrical data - Safety inputs | |
Safety inputs | X1 and X2 |
Rated operating voltage Ue | 24 VDC −15% / +10% |
Electrical data - Safety outputs | |
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Number of secure semi-conductor outputs | 2 |
Max. output current at secured output | 0,25 A |
Rated operating voltage | min. (Ue − 1 V) |
Residual current Ir | ≤ 0,5 mA |
Operating current Ie | max. 0,25 A |
- Ambient temperature: −25 °C … +70 °C | ≤ 0,1 A |
Minimum operating current Im | 0,5 mA |
- Ambient temperature: −25 °C … +65 °C | ≤ 0,25 A |
Utilisation category | DC-12: 24 V / 0,25 A DC-13: 24 V / 0,25 A |
Voltage drop Ud | < 1 V |
Electrical data - Diagnostic output | |
Serial diagnostics (Y/N) | No |
Fuse rating | short-circuit proof |
Design of control output | p-type |
Number of semi-conductor outputs with signaling function | 1 |
Rated operating voltage | Ue < 2 V |
Operating current Ie | max. 0,05 A |
Utilisation category | DC-12: 24 V / 0,05 A DC-13: 24 V / 0,05 A |
LED switching conditions display | |
LED switching conditions display (Y/N) | Yes |
Number of LED´s | 3 |
green LED | Supply voltage |
red LED | Error |
yellow LED | switching condition |
ATEX | |
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
Dimensions | |
Dimensions of the sensor | |
- Width of sensor | 106.3 |
- Height of sensor | 25 |
- Length of sensor | 22 |