Mechanical data |
|
Design of electrical connection |
IDC method of termination |
Cable section |
- Min. Cable section |
1 x 0,75 |
- Max. Cable section |
1 x 1.0, flexible |
Mechanical life |
> 1.000.000 operations |
Emergency unlocking device (Y/N) |
No |
Manual release (Y/N) |
Yes |
- bottom |
Emergency release (Y/N) |
No |
Latching force |
30 |
Positive break force |
17 |
positive break travel |
11 mm |
Clamping force F |
1000 N |
Max. Actuating speed |
2 m/s |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature |
−25 °C |
- Max. environmental temperature |
+60 °C |
Protection class |
IP67 to IEC/EN 60529 |
|
Electrical data |
|
Design of control element |
Opener (NC) |
notice |
change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges |
Switching principle |
Creep circuit element |
Number of auxiliary contacts |
0 |
Number of safety contacts |
2 |
Power to unlock |
No |
Power to lock |
Yes |
Rated control voltage Us |
24 VAC/DC |
Power consumption |
max. 10 W |
Rated impulse withstand voltage Uimp |
4 kV |
Rated insulation voltage Ui |
250 V |
Thermal test current Ithe |
10 A |
Utilisation category |
AC-15: 230 V / 4 A, DC-13: 24 V / 4 A |
Max. fuse rating |
6 A gG D-fuse |
|
ATEX |
|
Explosion protection categories for gases |
None |
Explosion protected category for dusts |
None |
|
Miscellaneous data |
|
Applications |
sliding safety guard,
removable guard,
hinged safety guard |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor |
90 |
- Height of sensor |
84 |
- Length of sensor |
30 mm |