ZSD5 101199467
| Mechanical data | |
| Design of electrical connection | Screw connection |
| Cable section | |
| - Min. Cable section | 0,14 mm² |
| - Max. Cable section | 1.5 mm² |
| Mechanical life | Normally-open contact: Level 1 - 2 - 1: 1.000.000 operations Level 1 - 2 - 3 - 1: 100.000 operations |
| Switching frequency | max. 1200 /h |
| Additional push-button (Y/N) | No |
Подробно описание
| Ambient conditions | |
| Ambient temperature | |
| - Min. environmental temperature | −10 °C |
| - Max. environmental temperature | +60 °C |
| Protection class | IP65 |
| Electrical data | |
| Design of control element | Normally open contact (NO), Opener (NC) |
| Switching principle | Slow action |
- positive break NC contact (from Level 2 To Level 3) |
|
| Number of shutters | 2 |
| Number of openers | 1 |
| Rated impulse withstand voltage Uimp | 2.5 kV |
| Rated operating voltage Ue | 250 VAC/DC |
| Operating current Ie | 3.0 A |
| Utilisation category | |
| - Normally-open contact: | Contact configuration: 2 Normally open contact (NO) AC-15: 125 V / 1,5 A; 250 V / 0,75 A DC-13: 30 V / 1,0 A; 125 V / 0,22 A; 250 V / 0,1 A Level 2 - 3: Positive break NC contact |
| - Auxiliary contact: | Contact configuration: 1 Opener (NC) AC-15: 125 V / 1,0 A; 250 V / 0,75 A DC-13: 30 V / 2,3 A; 125 V / 0,22 A; 250 V / 0,1 A |
| Max. fuse rating | 3 A gG D-fuse |
| notice | |
| Customer-specific versions, with connecting cable, are available upon request. | |
| The monitoring module must offer the possibility of cross-wire monitoring. | |
| Only a double shielded cable is authorised as supply line. | |
| 1) If the device is used in humid or damp rooms, a suitable connecting cable must be used. | |
| 1) The impact and fire resistance of this device has been examined to UL508. | |
| Diagram | |
![]() Note Diagram |
|
(from Level 2 To Level 3)