Electrical data | |
Rated DC voltage for controls | |
- Max. rated DC voltage for controls | 20.4 |
- Max. rated DC voltage for controls | 28.8 |
Rated AC voltage for controls, 50 Hz | |
- Min. rated AC voltage for controls, 50 Hz | 20.4 |
- Max. rated AC voltage for controls, 50 Hz | 26.4 |
Rated AC voltage for controls, 60 Hz | |
- Min. rated AC voltage for controls, 60 Hz | 20.4 |
- Max. rated AC voltage for controls, 60 Hz | 26.4 |
Contact resistance | max. 100 mΩ |
Power consumption | max. 1.7 W; 1.9 VA |
Type of actuation | AC/DC |
Rated operating voltage Ue | 24 VDC −15% / +20%, residual ripple max. 10% 24 VAC −15% / +10% |
Operating current Ie | 0,08 A |
Frequency range | 50 / 60 HZ |
Electronic protection (Y/N) | No |
Fuse rating for the operating voltage | 0,5 A gG D-fuse |
Outputs | |
Stop category | 0 |
Number of safety contacts | 3 piece |
Number of auxiliary contacts | 1 piece |
Number of signalling outputs | 0 piece |
Switching capacity | |
- Switching capacity of the safety contacts | max. 250 VAC, 6 A ohmic (inductive in case of appropriate protective wiring) min. 10 V, 10 mA |
- Switching capacity of the auxiliary contacts | 24 VDC, 2 A |
Fuse rating | |
- Protection of the safety contacts | 6 A slow blow |
- Fuse rating for the auxiliary contacts | 2 A slow blow |
Utilisation category To EN 60947-5-1 | AC-15: 230 V / 6 A DC-13: 24 V / 6 A |
Number of undelayed semi-conductor outputs with signaling function | 0 piece |
Number of undelayed outputs with signaling function (with contact) | 1 piece |
Number of delayed semi-conductor outputs with signaling function. | 0 piece |
Number of delayed outputs with signalling function (with contact). | 0 piece |
Number of secure undelayed semi-conductor outputs with signaling function | 0 piece |
Number of secure, undelayed outputs with signaling function, with contact. | 3 piece |
Number of secure, delayed semi-conductor outputs with signaling function | 0 piece |
Number of secure, delayed outputs with signaling function (with contact). | 0 piece |
LED switching conditions display | |
LED switching conditions display (Y/N) | Yes |
Number of LED´s | 4 |
LED switching conditions display | |
- The integrated LEDs indicate the following operating states. | |
- Position relay K1 | |
- Position relay K2 | |
- Supply voltage | |
- Internal operating voltage Ui | |
Miscellaneous data | |
Applications | Emergency-Stop button Guard system Pull-wire emergency stop switches |
Dimensions | |
Dimensions | |
- Width | 22.5 mm |
- Height | 100 mm |
- Depth | 121 mm |